If mould comes back on exactly the same strip of wall every winter, above a window, along a ceiling edge or in one corner, a cold bridge is often the reason. A cold bridge, also called a thermal bridge, is a part of the building that lets heat escape faster than the wall around it. Its inside surface stays colder, so moist room air condenses there first and keeps it damp for longer. Understanding where the bridge is helps you choose a fix that lasts rather than cleaning the same patch each year.

  • Checkatrade 9.82 (389 reviews)
  • Google 4.9
  • 20-year DPC guarantee

Book your free damp survey

No obligation. We usually call back the same day.

By sending this form you agree to our privacy policy

Written by Seth Long, Damp Pro and Co · Last updated: 26 November 2026

Need this sorted?

Need help with condensation control? Get a quote from Damp Pro and Co.

How a cold bridge works

Heat always travels towards the cold. Most of a wall slows that movement down, especially if it has a cavity or insulation. Some parts conduct heat much more easily: dense concrete or steel lintels, solid concrete floor edges, the junction where a wall meets the roof, and places where insulation is missing or has slumped. Heat rushes out through these routes, so the inner surface at that point can be several degrees cooler than the plaster a few centimetres away. When warm, humid air touches it, it reaches its dew point and water forms on the surface.

Where cold bridges usually show

Look for mould or damp lines that follow the shape of the building rather than a leak:

  • A horizontal band above a window or door where the lintel sits
  • Vertical lines in external corners, where two outside walls meet
  • The strip where an external wall meets the ceiling under the eaves
  • Around the edge of a solid floor at skirting level
  • Window reveals where the cavity has not been closed with insulation
  • Patches where loft insulation stops short of the wall head
  • Grid-like lines on ceilings or walls that follow joists or fixings

Telling a cold bridge from other damp

Cold bridge mould tends to have a neat outline, appears in the coldest months, and is worse in rooms that produce more moisture, such as bedrooms and bathrooms. The plaster usually feels cold rather than wet, and it dries out in summer. Penetrating damp, in contrast, often follows the rain and may leave brown staining or salts. Rising damp stays low on the wall and shows a tide mark. If a patch is wet during dry weather or leaves salt deposits, it is unlikely to be condensation alone.

A simple temperature check

An infrared thermometer, which costs little from a DIY shop, can show the difference. On a cold morning, measure the surface temperature of the suspect area and of a clear section of the same wall. A noticeably lower reading on the mouldy patch supports the idea of a cold bridge. Pair this with a hygrometer reading of room humidity: high humidity and a cold patch together are a strong recipe for condensation. Thermal imaging used during a survey does the same thing over a whole wall and is useful for spotting missing insulation.

Lowering the moisture in the room

Because the cold spot will always be the first place water forms, cutting the amount of moisture in the air is the quickest improvement. Use extractor fans in kitchens and bathrooms, keep trickle vents open, dry washing outside or in a well-ventilated room, and put lids on pans. Keep humidity in the mid range rather than letting it climb towards the top of the scale overnight. These steps will not remove the bridge, but they reduce how often the surface gets wet.

Keeping the surface warmer

Steady, moderate heating is better than short bursts. A room that is cold all day and heated quickly in the evening leaves walls cool while the air warms up, which encourages condensation. Avoid pushing beds, wardrobes and sofas tight against the affected wall, because they block warm air from reaching it. Curtains that fully cover a cold window reveal can also trap cold, moist air against the glass and frame overnight.

Building fixes for persistent cases

Where the bridge is severe, a lasting fix means adding insulation at the weak point. Options can include topping up loft insulation so it meets the top of the wall, fitting insulated plasterboard to a cold reveal or lintel area, closing an open cavity around a window, or insulating a section of wall internally. Each has to be detailed carefully so moisture is not trapped behind the new layer. On older solid walls, breathable materials are often more suitable than impermeable boards. Get advice before starting, because poorly fitted insulation can move the cold spot rather than remove it.

Cleaning the mould already there

Small areas on hard, painted surfaces can usually be cleaned with a mould product used as directed, with gloves, a mask and a window open. Wipe rather than brush. After cleaning, a mould-resistant paint can slow regrowth on the surface, but it will not warm the wall. Large areas, mould on porous materials and households with people who have asthma or weakened immunity are better dealt with by a professional, and the NHS advises seeking medical advice if symptoms are a concern.

When a cold spot points to something else

Occasionally what looks like a cold bridge is a gap in cavity wall insulation, wet insulation in a filled cavity or a defective cavity tray letting water reach the inner leaf. These cases can look like condensation in winter but persist after heating and ventilation improve. If changes to habits and extraction do not help within a season, an inspection is worthwhile.

Further help

Our condensation control service looks at ventilation, extraction and advice on cold spots together. Related guides on cavity closers and ideal humidity in the house explain two of the most common contributing factors. If mould keeps appearing on the same line, book a free damp survey and we will check whether it is condensation, a cold bridge or a different source of damp.

Want a professional to handle it?

Arrange a survey to find out what your home needs.

Related services

Covering Ruislip, West London and South Bucks.

Questions about this topic

What is cold bridging?

It is a part of the building, such as a lintel, corner or uninsulated gap, that lets heat escape faster than the surrounding wall, leaving a colder inside surface where condensation forms.

Why does mould grow above my window?

The lintel above a window is often a cold bridge. Moist air condenses on that colder strip, which keeps it damp enough for mould.

Will a dehumidifier fix cold bridging?

It can reduce how often the cold spot gets wet, but it does not warm the surface. Persistent cases may need insulation at that point.

Is cold bridging the same as rising damp?

No. Cold bridging causes condensation on cold surfaces, while rising damp is ground moisture moving up a wall and usually leaves a tide mark and salts low down.

Related guides

  • Cavity closers

    Damp and mould around window and door reveals when the cavity is not closed properly.

  • Humidity in the house

    Relative humidity, meter placement and cold-surface clues.

  • Trickle vents

    Background ventilation, condensation after new windows and whether to keep vents open in winter.

See all damp guides

Worried about damp? Book your free survey today.

Open 24 hours. Over 30 years' experience. 20-year guarantee on completed DPC work.

Book your free damp survey

No obligation. We usually call back the same day.

By sending this form you agree to our privacy policy

Freephone:0800 593 0300Mobile:07803 253337Book a free damp survey